{"id":1007,"date":"2015-12-29T17:05:02","date_gmt":"2015-12-29T15:05:02","guid":{"rendered":"http:\/\/n.megatron.co.il\/?p=1007"},"modified":"2016-01-04T10:09:05","modified_gmt":"2016-01-04T08:09:05","slug":"protection-against-input-voltage-change-mvdd-p-mvdd-r","status":"publish","type":"post","link":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/","title":{"rendered":"Protection against input voltage change &#8211; MVDD-P &#8211; MVDD-R"},"content":{"rendered":"<div class=\"ui-row row\">\n <div   class=\"ui-column span6\"><div class=\"auto-format ui--animation\"><p><strong>General Description<\/strong><\/p>\n<p>MVDD module is designed for the protection of the electronic device to the network voltage changes when the network drops below or exceeds Low Set over Set Hi exit relay is released. The thresholds are determined by two internal potentiometers HI and LO. Not only protects against power surges and high speed but its voltage rises or falls slowly. Disconnect speed up to 100 msec.<\/p>\n<p><strong>Specifications<\/strong><\/p>\n<p>Input: 230 VAC<br \/>\narea of &#8220;normal&#8221;: VAC 190 \uf07b 245 (or to order)<br \/>\nRelease date: MVVD-R &#8211; contact relay 5A \/ 250VAC;<br \/>\nMVVD-P &#8211; port input voltage 230 VAC<br \/>\n(Load Max 5A)<br \/>\nDimensions: x 79 93 x 25 mm (box UEGM 25)<br \/>\nInstallation: on DIN strip<br \/>\nfuse: in MVVD-P &#8211; 2A<\/p>\n<\/div><\/div> \n\n <div   class=\"ui-column span6\"><div class=\"ui--image-wrap clearfix\"><img decoding=\"async\"  id=\"ui--image-1\" class=\"ui--image ui--animation\" src=\"https:\/\/megatron.co.il\/wp-content\/uploads\/2015\/12\/mvdd-2.PNG\" alt=\"\u05d4\u05d2\u05e0\u05d4 \u05d1\u05e4\u05e0\u05d9 \u05e9\u05d9\u05e0\u05d5\u05d9 \u05de\u05ea\u05d7 \u05d4\u05d6\u05e0\u05d4 - MVDD-P - MVDD-R\" title=\"\" data-at2x=\"\"\/><\/div><\/div> \n\n<\/div> \n<div  class=\"ui--divider ui--animation clearfix ui--divider-solid-line\"><\/div><div  class=\"ui--space clearfix\" data-responsive=\"{&quot;css&quot;:{&quot;height&quot;:{&quot;phone&quot;:null,&quot;tablet&quot;:null,&quot;widescreen&quot;:null}}}\"><\/div><div class=\"ui-row row\">\n <div   class=\"ui-column span4\"><div id=\"arpw-widget-2\" class=\"widget widget-footer arpw-widget-random\"><h4 class=\"footer-widget-title ui--widget-title\">You May Also Like&#8230; <\/h4><div class=\"arpw-random-post \"><ul class=\"arpw-ul\"><li class=\"arpw-li arpw-clearfix\"><a href=\"https:\/\/megatron.co.il\/en\/vibrate-level-sensor-vn-4020\/\"  rel=\"bookmark\"><img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"50\" src=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/VN4020_front_logo_RGB-50x50.jpg\" class=\"arpw-thumbnail alignleft wp-post-image\" alt=\"Vibrate Level Sensor &#8211; VN 4020\" \/><\/a><a class=\"arpw-title\" href=\"https:\/\/megatron.co.il\/en\/vibrate-level-sensor-vn-4020\/\" rel=\"bookmark\">Vibrate Level Sensor &#8211; VN 4020<\/a><\/li><li class=\"arpw-li arpw-clearfix\"><a href=\"https:\/\/megatron.co.il\/en\/continuous-level-measurement-nivobob\/\"  rel=\"bookmark\"><img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"50\" src=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/NB4100_weight_PVC_version_front_RGB-50x50.jpg\" class=\"arpw-thumbnail alignleft wp-post-image\" alt=\"Continuous Level Measurement &#8211; Nivobob\u00ae\" \/><\/a><a class=\"arpw-title\" href=\"https:\/\/megatron.co.il\/en\/continuous-level-measurement-nivobob\/\" rel=\"bookmark\">Continuous Level Measurement &#8211; Nivobob\u00ae<\/a><\/li><li class=\"arpw-li arpw-clearfix\"><a href=\"https:\/\/megatron.co.il\/en\/isolated-signal-transducer-miscn\/\"  rel=\"bookmark\"><img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"50\" src=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/miscn-50x50.png\" class=\"arpw-thumbnail alignleft wp-post-image\" alt=\"Isolated Signal transducer &#8211; MISCN\" srcset=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/miscn-50x50.png 50w, https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/miscn-150x150.png 150w, https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/miscn-300x300.png 300w, https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/miscn-20x20.png 20w, https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/miscn.png 359w\" sizes=\"auto, (max-width: 50px) 100vw, 50px\" \/><\/a><a class=\"arpw-title\" href=\"https:\/\/megatron.co.il\/en\/isolated-signal-transducer-miscn\/\" rel=\"bookmark\">Isolated Signal transducer &#8211; MISCN<\/a><\/li><\/ul><\/div><!-- Generated by https:\/\/wordpress.org\/plugins\/advanced-random-posts-widget\/ --><\/div><\/div> \n\n <div   class=\"ui-column span4\"><div id=\"arpw-widget-3\" class=\"widget widget-footer arpw-widget-random\"><h4 class=\"footer-widget-title ui--widget-title\">Most Searched<\/h4><div class=\"arpw-random-post \"><ul class=\"arpw-ul\"><li class=\"arpw-li arpw-clearfix\"><a href=\"https:\/\/megatron.co.il\/en\/water-flow-impeller\/\"  rel=\"bookmark\"><img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"50\" src=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/20150309110021_F3.00_general_image-50x50.jpg\" class=\"arpw-thumbnail alignleft wp-post-image\" alt=\"Water flow &#8211; impeller\" srcset=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/20150309110021_F3.00_general_image-50x50.jpg 50w, https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/20150309110021_F3.00_general_image-150x150.jpg 150w\" sizes=\"auto, (max-width: 50px) 100vw, 50px\" \/><\/a><a class=\"arpw-title\" href=\"https:\/\/megatron.co.il\/en\/water-flow-impeller\/\" rel=\"bookmark\">Water flow &#8211; impeller<\/a><\/li><li class=\"arpw-li arpw-clearfix\"><a href=\"https:\/\/megatron.co.il\/en\/hydrostatic-level-transmitter-for-sewage\/\"  rel=\"bookmark\"><img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"50\" src=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/LMP633-NCNe999b6e793b7e794b5e5aeb9e68a95e585a5e5bc8fe6b6b2e4bd8de58f98e98081e599a8-50x50.png\" class=\"arpw-thumbnail alignleft wp-post-image\" alt=\"Hydrostatic Level Transmitter For Sewage\" srcset=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/LMP633-NCNe999b6e793b7e794b5e5aeb9e68a95e585a5e5bc8fe6b6b2e4bd8de58f98e98081e599a8-50x50.png 50w, https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/LMP633-NCNe999b6e793b7e794b5e5aeb9e68a95e585a5e5bc8fe6b6b2e4bd8de58f98e98081e599a8-150x150.png 150w\" sizes=\"auto, (max-width: 50px) 100vw, 50px\" \/><\/a><a class=\"arpw-title\" href=\"https:\/\/megatron.co.il\/en\/hydrostatic-level-transmitter-for-sewage\/\" rel=\"bookmark\">Hydrostatic Level Transmitter For Sewage<\/a><\/li><li class=\"arpw-li arpw-clearfix\"><a href=\"https:\/\/megatron.co.il\/en\/defense-units-mgd-mgdf\/\"  rel=\"bookmark\"><img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"50\" src=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mgd-50x50.png\" class=\"arpw-thumbnail alignleft wp-post-image\" alt=\"Defense Units &#8211; MGD &#8211; MGDF\" srcset=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mgd-50x50.png 50w, https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mgd-150x150.png 150w\" sizes=\"auto, (max-width: 50px) 100vw, 50px\" \/><\/a><a class=\"arpw-title\" href=\"https:\/\/megatron.co.il\/en\/defense-units-mgd-mgdf\/\" rel=\"bookmark\">Defense Units &#8211; MGD &#8211; MGDF<\/a><\/li><\/ul><\/div><!-- Generated by https:\/\/wordpress.org\/plugins\/advanced-random-posts-widget\/ --><\/div><\/div> \n\n <div   class=\"ui-column span4\"><div id=\"arpw-widget-4\" class=\"widget widget-footer arpw-widget-random\"><h4 class=\"footer-widget-title ui--widget-title\">Popular Products<\/h4><div class=\"arpw-random-post \"><ul class=\"arpw-ul\"><li class=\"arpw-li arpw-clearfix\"><a href=\"https:\/\/megatron.co.il\/en\/triple-transducer-mvat-daul-transducer-mvaft\/\"  rel=\"bookmark\"><img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"50\" src=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvat-50x50.png\" class=\"arpw-thumbnail alignleft wp-post-image\" alt=\"Triple Transducer &#8211; MVAT &#8211; Daul Transducer &#8211; MVAFT\" srcset=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvat-50x50.png 50w, https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvat-150x150.png 150w\" sizes=\"auto, (max-width: 50px) 100vw, 50px\" \/><\/a><a class=\"arpw-title\" href=\"https:\/\/megatron.co.il\/en\/triple-transducer-mvat-daul-transducer-mvaft\/\" rel=\"bookmark\">Triple Transducer &#8211; MVAT &#8211; Daul Transducer &#8211; MVAFT<\/a><\/li><li class=\"arpw-li arpw-clearfix\"><a href=\"https:\/\/megatron.co.il\/en\/dynameters-ultrasonic-flow-measurement\/\"  rel=\"bookmark\"><img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"50\" src=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2016\/01\/2011-1-26.222.44.140_14946-50x50.gif\" class=\"arpw-thumbnail alignleft wp-post-image\" alt=\"Dynameters &#8211; Ultrasonic Flow Measurement\" \/><\/a><a class=\"arpw-title\" href=\"https:\/\/megatron.co.il\/en\/dynameters-ultrasonic-flow-measurement\/\" rel=\"bookmark\">Dynameters &#8211; Ultrasonic Flow Measurement<\/a><\/li><li class=\"arpw-li arpw-clearfix\"><a href=\"https:\/\/megatron.co.il\/en\/indicator-flow-level-impeller-controller-mdi-fls-mic-1-fls\/\"  rel=\"bookmark\"><img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"50\" src=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/2mdi-fls-50x50.png\" class=\"arpw-thumbnail alignleft wp-post-image\" alt=\"Indicator &#8211; flow level impeller controller &#8211; MDI-FLS &#8211; MIC-1-FLS\" \/><\/a><a class=\"arpw-title\" href=\"https:\/\/megatron.co.il\/en\/indicator-flow-level-impeller-controller-mdi-fls-mic-1-fls\/\" rel=\"bookmark\">Indicator &#8211; flow level impeller controller &#8211; MDI-FLS &#8211; MIC-1-FLS<\/a><\/li><\/ul><\/div><!-- Generated by https:\/\/wordpress.org\/plugins\/advanced-random-posts-widget\/ --><\/div><\/div> \n\n<\/div> \n","protected":false},"excerpt":{"rendered":"<p>\u05ea\u05d0\u05d5\u05e8 \u05db\u05dc\u05dc\u05d9 MDI-FLS &#8211; \u05de\u05d7\u05d5\u05d5\u05df \u05d3\u05d2\u05d9\u05d8\u05dc\u05d9\u05dd \u05de\u05d9\u05d5\u05e2\u05d3 \u05dc\u05d4\u05e6\u05d2\u05ea \u05d0\u05d5\u05ea \u05db\u05e0\u05d9\u05e1\u05d4 \u05de\u05e8\u05d2\u05e9 \u05d4\u05d6\u05e8\u05d9\u05de\u05d4 \u05de\u05e1\u05d5\u05d2 \u05d0\u05d9\u05de\u05e4\u05dc\u05e8 (\u05ea\u05d5\u05e6\u05e8\u05ea \u05d7\u05d1'(FLS . MIC-1-FLS &#8211; \u05d1\u05e7\u05e8 \u05e2\u05dd \u05de\u05d2\u05e2 \u05de\u05d7\u05dc\u05d9\u05e3 \u05d0\u05d7\u05d3. \u05e0\u05e7\u05d5\u05d3\u05d5\u05ea Set-point \u05d0\u05e4\u05e9\u05e8 \u05dc\u05e7\u05d1\u05d5\u05e2 \u05e2&#8221;\u05d9 \u05e4\u05d5\u05d8&#8217; \u05d4\u05e0\u05de\u05e6\u05d0 \u05d1\u05d7\u05d6\u05d9\u05ea \u05e9\u05dc \u05d4\u05de\u05db\u05e9\u05d9\u05e8. You May Also Like&#8230; Multiplexers &#8211; MUX-CDC \/ MUX-VDCGear FlowmetersDFM digital mass flow meter Most SearchedELECTRONIC ASSEMBLYRotary Paddle Level Switch &#8211; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1372,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[31,164],"tags":[179,41],"class_list":["post-1007","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-megatron-elect-controls-products","category-monitors-and-alerts","tag-protection-against-input-voltage-change","tag-transmitters"],"aioseo_notices":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Protection against input voltage change - MVDD-P - MVDD-R - Megatron Electronics &amp; Controls<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Protection against input voltage change - MVDD-P - MVDD-R - Megatron Electronics &amp; Controls\" \/>\n<meta property=\"og:description\" content=\"Description The Megatron Microprocessor Annunciator MMA-182 monitors any parameter converted to an electrical signal: level, Temperature, flow, pressure, humidity, voltage, current etc. The Annunciator produces audio and visual alarms when a deviation from the normal occures. Specification Power supply: 220 \/ 110 VAC or 60 \/ 24 VDC Input: Dry contacts or Voltage up to [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/\" \/>\n<meta property=\"og:site_name\" content=\"Megatron Electronics &amp; Controls\" \/>\n<meta property=\"article:published_time\" content=\"2015-12-29T15:05:02+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-01-04T08:09:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvdd.png\" \/>\n\t<meta property=\"og:image:width\" content=\"127\" \/>\n\t<meta property=\"og:image:height\" content=\"205\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Elchai\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elchai\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/\"},\"author\":{\"name\":\"Elchai\",\"@id\":\"https:\/\/megatron.co.il\/en\/#\/schema\/person\/773c19937b96994066517a8dceba3890\"},\"headline\":\"Protection against input voltage change &#8211; MVDD-P &#8211; MVDD-R\",\"datePublished\":\"2015-12-29T15:05:02+00:00\",\"dateModified\":\"2016-01-04T08:09:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/\"},\"wordCount\":9,\"image\":{\"@id\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvdd.png\",\"keywords\":[\"Protection against input voltage change\",\"Transmitters\"],\"articleSection\":[\"Megatron Elect. &amp; Controls Products\",\"Monitors and alerts\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/\",\"url\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/\",\"name\":\"Protection against input voltage change - MVDD-P - MVDD-R - Megatron Electronics &amp; Controls\",\"isPartOf\":{\"@id\":\"https:\/\/megatron.co.il\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvdd.png\",\"datePublished\":\"2015-12-29T15:05:02+00:00\",\"dateModified\":\"2016-01-04T08:09:05+00:00\",\"author\":{\"@id\":\"https:\/\/megatron.co.il\/en\/#\/schema\/person\/773c19937b96994066517a8dceba3890\"},\"breadcrumb\":{\"@id\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#primaryimage\",\"url\":\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvdd.png\",\"contentUrl\":\"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvdd.png\",\"width\":127,\"height\":205,\"caption\":\"Protection against input voltage change - MVDD-P - MVDD-R\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u05d3\u05e3 \u05d4\u05d1\u05d9\u05ea\",\"item\":\"https:\/\/megatron.co.il\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Protection against input voltage change &#8211; MVDD-P &#8211; MVDD-R\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/megatron.co.il\/en\/#website\",\"url\":\"https:\/\/megatron.co.il\/en\/\",\"name\":\"Megatron Electronics &amp; Controls\",\"description\":\"flow meters, controls, level meter, temp and pressure measurement \",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/megatron.co.il\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/megatron.co.il\/en\/#\/schema\/person\/773c19937b96994066517a8dceba3890\",\"name\":\"Elchai\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/megatron.co.il\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/1008456eb4a0c7f3f30f6230ed75af48?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/1008456eb4a0c7f3f30f6230ed75af48?s=96&d=mm&r=g\",\"caption\":\"Elchai\"},\"description\":\"S. Admin\",\"url\":\"https:\/\/megatron.co.il\/en\/author\/elchai\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Protection against input voltage change - MVDD-P - MVDD-R - Megatron Electronics &amp; Controls","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/","og_locale":"en_US","og_type":"article","og_title":"Protection against input voltage change - MVDD-P - MVDD-R - Megatron Electronics &amp; Controls","og_description":"Description The Megatron Microprocessor Annunciator MMA-182 monitors any parameter converted to an electrical signal: level, Temperature, flow, pressure, humidity, voltage, current etc. The Annunciator produces audio and visual alarms when a deviation from the normal occures. Specification Power supply: 220 \/ 110 VAC or 60 \/ 24 VDC Input: Dry contacts or Voltage up to [&hellip;]","og_url":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/","og_site_name":"Megatron Electronics &amp; Controls","article_published_time":"2015-12-29T15:05:02+00:00","article_modified_time":"2016-01-04T08:09:05+00:00","og_image":[{"width":127,"height":205,"url":"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvdd.png","type":"image\/png"}],"author":"Elchai","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elchai"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#article","isPartOf":{"@id":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/"},"author":{"name":"Elchai","@id":"https:\/\/megatron.co.il\/en\/#\/schema\/person\/773c19937b96994066517a8dceba3890"},"headline":"Protection against input voltage change &#8211; MVDD-P &#8211; MVDD-R","datePublished":"2015-12-29T15:05:02+00:00","dateModified":"2016-01-04T08:09:05+00:00","mainEntityOfPage":{"@id":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/"},"wordCount":9,"image":{"@id":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#primaryimage"},"thumbnailUrl":"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvdd.png","keywords":["Protection against input voltage change","Transmitters"],"articleSection":["Megatron Elect. &amp; Controls Products","Monitors and alerts"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/","url":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/","name":"Protection against input voltage change - MVDD-P - MVDD-R - Megatron Electronics &amp; Controls","isPartOf":{"@id":"https:\/\/megatron.co.il\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#primaryimage"},"image":{"@id":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#primaryimage"},"thumbnailUrl":"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvdd.png","datePublished":"2015-12-29T15:05:02+00:00","dateModified":"2016-01-04T08:09:05+00:00","author":{"@id":"https:\/\/megatron.co.il\/en\/#\/schema\/person\/773c19937b96994066517a8dceba3890"},"breadcrumb":{"@id":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#primaryimage","url":"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvdd.png","contentUrl":"https:\/\/megatron.co.il\/en\/wp-content\/uploads\/sites\/2\/2015\/12\/mvdd.png","width":127,"height":205,"caption":"Protection against input voltage change - MVDD-P - MVDD-R"},{"@type":"BreadcrumbList","@id":"https:\/\/megatron.co.il\/en\/protection-against-input-voltage-change-mvdd-p-mvdd-r\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u05d3\u05e3 \u05d4\u05d1\u05d9\u05ea","item":"https:\/\/megatron.co.il\/en\/"},{"@type":"ListItem","position":2,"name":"Protection against input voltage change &#8211; MVDD-P &#8211; MVDD-R"}]},{"@type":"WebSite","@id":"https:\/\/megatron.co.il\/en\/#website","url":"https:\/\/megatron.co.il\/en\/","name":"Megatron Electronics &amp; Controls","description":"flow meters, controls, level meter, temp and pressure measurement ","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/megatron.co.il\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/megatron.co.il\/en\/#\/schema\/person\/773c19937b96994066517a8dceba3890","name":"Elchai","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/megatron.co.il\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/1008456eb4a0c7f3f30f6230ed75af48?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1008456eb4a0c7f3f30f6230ed75af48?s=96&d=mm&r=g","caption":"Elchai"},"description":"S. Admin","url":"https:\/\/megatron.co.il\/en\/author\/elchai\/"}]}},"_links":{"self":[{"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/posts\/1007","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/comments?post=1007"}],"version-history":[{"count":1,"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/posts\/1007\/revisions"}],"predecessor-version":[{"id":1101,"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/posts\/1007\/revisions\/1101"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/media\/1372"}],"wp:attachment":[{"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/media?parent=1007"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/categories?post=1007"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/megatron.co.il\/en\/wp-json\/wp\/v2\/tags?post=1007"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}